AWS EDITION 1, 2009

(Tina Sui) #1

© 2009, AWI, AWMAC, WI - Architectural Woodwork Standards - 1st Edition, October 1, 2009 37


As may be updated by errata at http://www.awinet.org, http://www.awmac.com, or http://www.woodworkinstitute.com/awserrata/

37


PRODUCT


SHOP DRAWING RULES (continued)


DESCRIPTION



4.1


G E N E R A L


GENERAL requirements (continued)



4.1.6

D R A W I N G S


DRAWINGS shall (continued)
4.1.6.2

W A L L B L O C K I N G


Show centerline height and horizontal location of all required internal WALL BLOCKING furnished
by others by a standard convention such as:

4.1.6.2.1


82

52”

6”

32.5”


120”

150”

Blocking
Center Line

4.1.7


S A M P L E S


SAMPLES, if required of:

4.1.7.1

HARDWARE shall include one sample of each hardware item that will show in normal use when
cabinet doors and drawers are closed.
4.1.7.2

F I N I S H I N G

FINISHING shall:
4.1.7.2.1 Be a minimum of 12" x 12" (305 mm x 305 mm) for panel products
4.1.7.2.2 Be as wide as practical if on lumber by a minimum of 12" (304 mm) in length
4.1.7.2.3 Be on material representative of that to be used for the project

4.1.7.2.4 Bear a label identifying the date, job name, the design professional, the contractor, and the finish system name and number

4.1.7.2.5 For range of color and grain to be expected for each color selectionTRANSPARENT FINISH, require a minimum of three samples indicating the

4.1.7.2.6 For OPAQUE FINISH, require a minimum of four samples for each color selection
4.1.8 Submittals shall present FIRST-CLASS WORKMANSHIP in compliance with these standards.
4.2


SPECIFIC SECTION requirements


4.2.1


S E C T I O N 6 


SECTION 6 - INTERIOR & EXTERIOR MILLWORK


4.2.1.1


L I S T I N G S


LISTING requirements shall additionally include:
4.2.1.1.1 Related material requirements and specifications
4.2.1.1.2 TRIM SCHEDULE for each room or area, including as applicable:
4.2.1.1.2.1 Detail section reference
4.2.1.1.3

F R A M E S


FRAME, SASH, SCREEN, BLIND, and/or SHUTTER SCHEDULE for each room
or area, including as applicable:
4.2.1.1.3.1 Opening number and location
4.2.1.1.3.2 Elevation and/or section references
4.2.1.1.3.3 Opening size
4.2.1.1.3.4 Handing and pre-machining requirements
4.2.1.1.3.5 Hardware types and locations
4.2.1.1.3.6 Screen specifications

Section 1 - Submittals (Page 4 of 9)


1

Free download pdf