AWS EDITION 1, 2009

(Tina Sui) #1

413


Appendix B


© 2009, AWI, AWMAC, WI - Architectural Woodwork Standards - 1st Edition, October 1, 2009


(Appendix B is not part of the AWS for compliance purposes)

C. [Mockups:
Mockups shouldn’t be necessary for most projects. Include this item if full sized samples are
desired.


  1. Provide mockups of one base cabinet, one wall hung cabinet, and one countertop. Base cabinet shall have
    at least one drawer. Mockup shall be of the material and finish to be provided. The Approved Mockup may
    be incorporated in the project.]


1.04 QUALITY ASSURANCE


A. Work shall be in accordance with the Grade or Grades specified of the Architectural Woodwork Standards.

B. [Association Quality Assurance Program.]
Association quality assurance programs provide a pre qualification for the sub contractor. Bidders
will be Association program participants or they will understand that their work will be inspected
by an Association program representative. For better quality assurance, it’s recommended that an
Association assurance program is used.
C. Qualification:


  1. Firm (woodwork manufacturer) with no less than 5 years of production experience similar to a specific project,
    whose qualifications indicate the ability to comply with the requirements of this Section.

  2. The woodwork manufacturer must have at least one project in the past 5 years where the value of the woodwork
    was within 20 percent of the cost of woodwork for this Project.


D. Single Source Responsibility: A single manufacturer shall provide and install the work of described in this Section.

1.05 DELIVERY STORAGE AND HANDLING


A. Deliver materials only when the project is ready for installation and the general contractor has provided a clean storage
area.


  1. Delivery of architectural millwork shall be made only when the area of operation is enclosed, all plaster and concrete
    work is dry and the area broom clean.

  2. Maintain indoor temperature and humidity within the range recommended by the Architectural Woodwork Standards
    for the location of the project.


1.06 SCHEDULING


A. Coordinate fabrication, delivery, and installation with the general contractor and other applicable trades.

PART 2 - PRODUCTS


2.01 COMPONENTS


A. Lumber shall be in accordance with the Architectural Woodwork Standards Grade specified for the product being
fabricated. Moisture Content shall be 6% to 12% for boards up to 2” (50.8 mm) inch nominal thickness, and shall not
exceed 19% for thicker pieces.

B. Veneers shall be in accordance with the Architectural Woodwork Standards requirements for its use and the Grades.

C. Core shall be [MDF] [particleboard] meeting the requirements of Architectural Woodwork Standards.
Particleboard or MDF are recommended as core materials.

D. Veneer core plywood shall be a non-telegraphing hardwood manufactured with exterior glue.

E. Plastic Laminate shall meet the requirements of the Architectural Woodwork Standards for its intended use.

CSI Section 06 41 00


Wood and Plastic Laminate Casework