40
© 2009, AWI, AWMAC, WI - Architectural Woodwork Standards - 1st Edition, October 1, 2009
As may be updated by errata at http://www.awinet.org, http://www.awmac.com, or http://www.woodworkinstitute.com/awserrata/
40
PRODUCT
SHOP DRAWING RULES (continued)
DESCRIPTION
4.2
S P E C I F I C S E C T I O N R E Q U I R E M E N T S
SPECIFIC SECTION requirements (continued)
4.2.5
S E C T I O N
10
SECTION 10 - CASEWORK
4.2.5.1
L I S T I N G S
LISTING requirements shall additionally include:
4.2.5.1.1 Exposed surface materials and thickness
4.2.5.1.2 Semi-exposed surface materials
4.2.5.1.3 Concealed surface materials
4.2.5.1.4 Inside face of cabinet door material and thickness
4.2.5.1.5 Panel core thickness and type
4.2.5.1.6 Edgebanding material and thickness
4.2.5.1.7 Drawer box material and construction
4.2.5.1.8 Drawer slides or guides
4.2.5.1.9 Hinges with finish
4.2.5.1.10 Adjustable shelf pins, brackets, and/or standards
4.2.5.1.11 Miscellaneous finish hardware with finish and manufacturer's cut or spec sheet
4.2.5.1.12 Glass type(s) and thickness
4.2.5.1.13 Special metal work and/or specialty items
4.2.5.2
D R A W I N G S
DRAWINGS requirements shall include additionally, as applicable:
4.2.5.2.1 REFERENCE PLAN, so work areas can be located in building
4.2.5.2.2 TRIM and/or SCRIBE shown in full-size profile
4.2.5.2.3 CASEWORK, shown in plan, elevation, and section view, including:
4.2.5.2.3.1 Countertops, per the specific requirements for countertops
listed below
4.2.5.2.3.2 Details need not be drawn if properly referenced to a
supplementary document
4.2.5.2.3.3 Dimensions necessary to construct cabinets
4.2.5.2.3.4 Widths of face-frame members
4.2.5.2.3.5 Type and thickness of drawer members, including heights and depths
4.2.5.2.3.6 Type and thickness of cabinet doors
4.2.5.2.3.7 Section of each cabinet type or configuration
4.2.5.2.3.8 Details of all joinery and connections
4.2.5.2.3.9 Specification and location of special metal work and/or specialty items
4.2.5.2.3.10 Provision for field dimensions
4.2.5.2.3.11 Section details showing method of cabinet attachment to walls,
floors, and ceilings
4.2.5.2.4 Blocking or strapping requirements and their locations (blocking to be furnished
by others) shown on cabinet elevations with dimension off finished floor
4.2.6
SECTION 11 - COUNTERTOPS
4.2.6.1
LISTING requirements shall include, as applicable:
4.2.6.1.1 Core thickness and type
4.2.6.1.2 Exposed material description and thickness
4.2.6.1.3 Backing sheet at top and/or splash
4.2.6.1.4 Adhesive type
Section 1 - Submittals (Page 7 of 9)