AWS EDITION 1, 2009

(Tina Sui) #1

© 2009, AWI, AWMAC, WI - Architectural Woodwork Standards - 1st Edition, October 1, 2009 41


As may be updated by errata at http://www.awinet.org, http://www.awmac.com, or http://www.woodworkinstitute.com/awserrata/

41


PRODUCT


SHOP DRAWING RULES (continued)


DESCRIPTION



4.2


S P E C I F I C S E C T I O N R E Q U I R E M E N T S 


SPECIFIC SECTION requirements (continued)



4.2.6

S E C T I O N


11


SECTION 11 - COUNTERTOPS (continued)


4.2.6.1

LISTING requirements shall include (continued)

4.2.6.1.5 Type of sealing compound used to seal sink cutouts and/or splashes

4.2.6.2

D R A W I N G S


DRAWINGS shall include, as applicable:
4.2.6.2.1 In plan view
4.2.6.2.1.1 Each countertop with field joints
4.2.6.2.1.2 Sink size and location
4.2.6.2.1.3 Support brackets with notation, if furnished by others
4.2.6.2.2 In elevation view
4.2.6.2.2.1 Relationship to casework and support brackets
4.2.6.2.3 In section detail, minimum 3" = 1'-0" (1:5) scale
4.2.6.2.3.1 Front and/or end overhang
4.2.6.2.3.2 Front and/or end edge types
4.2.6.2.3.3 Splash type and height
4.2.6.2.3.4 Drip groove
4.2.6.2.3.5 End splash return
4.2.6.2.3.6 Field joints
4.2.6.2.4 Sink and sink rim types, if included
4.2.6.2.5 Joinery at field joints
4.2.6.2.6 Attachment to casework
4.2.7

S E C T I O N


12



SECTION 12 - HISTORIC RESTORATION WORK - NOTE: The above general and specific shop drawing
requirements shall prevail for a specific product type.
4.2.7.1 A written RESTORATION and CONSERVATION PROGRAM shall be developed with a qualified
wood conservator and submitted for each phase of the restoration process outlining:
4.2.7.1.1 Where extant wood materials will need to be removed, repaired, and retained,
including:

4.2.7.1.1.1 The means and methods to catalog the wood members,
remove, crate and protect, store, and reinstall

4.2.7.1.1.2 A plan for protection of surrounding materials, including
interface with other trades

4.2.7.1.1.3 A plan to retain toxic and/or offensive off-gassing and provide
adequate ventilation

4.2.7.1.1.4


A plan to date-stamp all new work in letters minimum 1/4"
(6.4 mm) high noting the month, year, and the installer’s or
manufacturer’s name in an area not exposed to view as a
record of when the work was installed
4.2.7.2


LISTING requirements shall include, as applicable:

4.2.7.2.1 Items to be repaired, including description, location, original material, and material to be used in repair

4.2.7.2.2 Items to be replaced, including description, location, material to be used, and basis for design

4.2.7.2.3


Specific restoration requirements for:
4.2.7.2.3.1 Removal
4.2.7.2.3.2 Storage

Section 1 - Submittals (Page 8 of 9)


1