© 2009, AWI, AWMAC, WI - Architectural Woodwork Standards - 1st Edition, October 1, 2009 47
As may be updated by errata at http://www.awinet.org, http://www.awmac.com, or http://www.woodworkinstitute.com/awserrata/
47
PRODUCT
CARE & STORAGE RULES (continued)
DESCRIPTION
4.1
G E N E R A L
GENERAL (continued)
4.1.2
M I L L W O R K
ARCHITECTURAL WOODWORK
4.1.2.1 While AWAITING INSTALLATION, shall be stored:
4.1.2.1.1 Flat on a level surface
4.1.2.1.2 At least 4” (101.6 mm) off the floor
4.1.2.1.3 With a cover to keep it clean, while permitting air circulation
4.1.2.2
I N T E R I O R
At INTERIOR application, shall be stored and/or installed in an area:
4.1.2.2.1 That is clean
4.1.2.2.2 That is dry and well ventilated
4.1.2.2.3 That is protected from sunlight and/or excessive heat
4.1.2.2.4 That is protected from moisture
4.1.2.2.5 That is between 60 - 90 degrees Fahrenheit (15.5 - 32 degrees Celsius) inclusive
4.1.2.2.6 That has a maintained Relative Humidity between 25 - 55% inclusive, except in:
4.1.2.2.6.1
The damp Southern Coastal areas of the U.S., Newfoundland,
and the Canadian Coastal Provinces shall be between
43 - 70% inclusive
4.1.2.2.6.2
The dry Southwestern U.S., and Alberta, Saskatchewan, and
Manitoba in Canada shall be between 17 - 50% inclusive
4.1.2.2.7 That has a maintained MC (Optimum Moisture Content) between 5 - 10%
inclusive, except in:
4.1.2.2.7.1
The damp Southern Coastal areas of the U.S., Newfoundland,
and Canadian Coastal Provinces shall be between 8 - 13%
inclusive
4.1.2.2.7.2 The dry Southwestern U.S., and Alberta, Saskatchewan, and
Manitoba in Canada shall be between 4 - 9% inclusive
4.1.2.2.8 To which it has been acclimated to for a minimum of 72 hours prior to installation
4.1.2.3 At EXTERIOR application, shall be stored and/or installed in an area that is:
4.1.2.3.1 Clean
4.1.2.3.2 Protected from direct moisture
4.1.2.3.3 Protected from direct sunlight
4.1.2.4
A C C E P T A N C E
After ACCEPTANCE:
4.1.2.4.1 At INTERIOR application:
4.1.2.4.1.1
Shall be maintained in the same environmental conditions as
during its storage and/or installation
4.1.2.4.1.2
Temperature in a building shall not be raised for a sustained
period of time to eliminate the OFF GASES; it will negatively
affect the appearance and performance of architectural
millwork
4.1.2.4.2 At EXTERIOR application shall:
4.1.2.4.2.1 Have its finish maintained, refinishing as necessary (especially oiled finishes)
4.1.2.4.2.2 Be protected from excessive moisture and standing water
4.1.2.4.3 SEVERE DAMAGE can result from not adhering to the above rules
4.1.2.4.3.1
FABRICATOR/INSTALLER shall not be held responsible for
the damage caused by not adhering to the above
Section 2 - Care & Storage (Page 4 of 5)
2