60 © 2009, AWI, AWMAC, WI - Architectural Woodwork Standards - 1st Edition, October 1, 2009
As may be updated by errata at http://www.awinet.org, http://www.awmac.com, or http://www.woodworkinstitute.com/awserrata/
Section 3 - Lumber (Page 11 of 18)
PRODUCT
LUMBER RULES (continued)
These rules are not intended to create a lumber grade; they are only intended to establish the acceptable requirements
and/or characteristics after the architectural woodwork is completed or installed.
DESCRIPTION E C P
4.2a
H A R D W O O D
MATERIAL - HARDWOOD (continued)
4.2a.11
T R A N S P A R E N T
TRANSPARENT FINISH (continued)
4.2a.11.3
L I M I T A T I O N S
NATURAL CHARACTERISTIC LIMITATIONS (continued)
4.2a.11.3.2 A maximum of THREE with: M
4.2a.11.3.2.1
NO knots, pitch streaks, or pitch pockets within 36"
(914 mm) of one another
M
4.2a.11.3.3 A maximum of TWO with: M
4.2a.11.3.3.1 NO(1219 mm) of one another. knots, pitch streaks, or pitch pockets within 48" M
4.2a.11.3.4 For: ASH, Natural MAPLE, Hard or Soft, Natural
BIRCH, Natural RED & WHITE OAK
MAHOGANY, Honduras TEAK
4.2a.11.3.4.1 NONE in any face smaller than 300 square inches
(7620 square mm), with:
M
4.2a.11.3.4.1.1
ONE permitted for each
additional 100 square inches
(2540 square mm)
M
4.2a.11.3.4.2 NONE in any face smaller than 400 square inches
(10160 square mm), with: M
4.2a.11.3.4.2.1
ONE permitted for each
additional 150 square inches
(3810 square mm)
M
4.2a.11.3.4.3 NONE in any face smaller than 600 square inches
(15240 square mm), with: M
4.2a.11.3.4.3.1
ONE permitted for each
additional 200 square inches
(5080 square mm)
M
4.2a.11.3.5 For: ASH, Select Brown BIRCH, Select Red & White MAPLE, Select White
4.2a.11.3.5.1 NONE in any face smaller than 200 square inches
(5080 square mm), with:
M
4.2a.11.3.5.1.1
ONE permitted for each
additional 100 square inches
(2540 square mm)
M
4.2a.11.3.5.2 NONE in any face smaller than 350 square inches
(8890 square mm), with: M
4.2a.11.3.5.2.1
ONE permitted for each
additional 150 square inches
(3810 square mm)
M
4.2a.11.3.5.3 NONE in any face smaller than 500 square inches
(12700 square mm), with: M
4.2a.11.3.5.3.1
ONE permitted for each
additional 200 square inches
(5080 square mm)
M
3