Hydraulic Structures: Fourth Edition

(Amelia) #1
in 3 and 1 in 8 are usually recommended. The discharge is given by
the following formula:

Q1.99LH3/2(H/B)1/6. (10.46)


  1. Design of cistern is as follows:


length, Lc5(EHdr)1/2; (10.47)

depth, dc

1


4


(EHdr)2/3. (10.48)


  1. Minimum length of impervious floor downstream of the crest,


Lbd2(D 1 1.2)Hdr. (10.49)

(c) YMGT-type drop (Japan)


This type of drop is generally used in flumed sections suitable for small
canals, field channels, etc., with discharges up to 1 m^3 s^1 (Fig. 10.19). The
following are the recommended design criteria:



  1. sill height, Pvaries from 0.06 m to 0.14 m with the unit discharge q
    between 0.2 and 1.0 m^3 s^1 m^1 ;

  2. depth of cistern, dc1/2(EcHdr)1/2; (10.50)

  3. length of cistern, Lc2.5Ld, (10.51)


DROP STRUCTURES 453


Fig. 10.19 YMGT-type drop, Japan (Kraatz and Mahajan, 1975)