DHARM646 GEOTECHNICAL ENGINEERINGAllowable soil pressures:
150 kN/m^2 for DL + reduced LL
225 kN/m^2 for DL + LLColumn loads
Column A Column B
DL 540 kN 690 kN
LL 400 kN 810 kN
Distance c/c of columns = 5.4 m
Projection of footing beyond column not to exceed 0.5 m.
Resultant Column Loads Column A Column B Total
DL + reduced LL 740 kN 1095 kN 1835 kN
DL + LL 940 kN 1500 kN 2440 kN
For uniform pressure under DL + reduced LL:
Let us use equal projections beyond columns A & B.
L′ = 5.4 m
L = L′ + 2e 1 = 5.4 + 2 × 0.5 = 6.4 m.
Total area required, A = 1835/150 = 12.23 m^2
x, distance of resultant column load from the left edge = 3.22 + 0.5 = 3.723.22 m 2.18 m740 kN R = 1835 kN 1095 kNL = 5.4 m¢
L = 6.4 m
0.5 m Section 0.5 m3.7 m 2.7 mCol. A Col. BPlan2440 kNC.G.e = 0.12 m
B = 1.05 m 2 B = 2.85 1Fig. 15.32 Trapezoidal combined footing (Ex. 15.5)∴ B 1 =^23121223
643372
64A 1
Lx
LF −
HGI
KJ= ××F −
HGI
KJ.
..
.= 2.85 mB 2 =^2 2 12 23(^164)
A
L
−=B
×.
.
- 2.85 = 1.05 m