DHARM
ELEMENTS OF SOIL DYNAMICS AND MACHINE FOUNDATIONS 869
Pressure on Foundation Soil
Total weight coming on the soil = (200 + 432) kN = 632 kN
Area of base = 6 × 3 = 18 m^2
∴ Stress on soil =
632
18
= 36.8 kN/m^2
Safe bearing capacity of the soil under static loading conditions = 100 kN/m^2
Assuming a reduction factor of 0.5,
dynamic bearing capacity = 50 kN/m^2
Since this is more than the stress on the soil the size is satisfactory.
Amplitudes of motion
ωn^2 =
CA
M
u =45 000 18×
632 9 81
,
(/.)
= 12,573/sec^2
ω^2 =
()600 2
60
×π^2
= 3.948/sec^2
Amplitude of vibration =
P
M n
0
()ωω^22 − , neglecting damping of soil.
=
P
M
z
n
max
()ωω^22 −
=
75 124
632 9 81 12573 3948
.
(/.)( − )
m
= 0.135 mm
Since the permissible amplitude is 0.15 mm, this is safe.
Note:- Moments due to unbalanced forces may be determined from appropriate data
regarding positioning of the compressor and the motor on the foundation block; also, analysis
for other modes of vibration such as sliding and rocking may also be performed and the corre-
sponding amplitudes may be obtained and verified.
Example 20.11: Design a suitable foundation for a double-acting steam hammer for the fol-
lowing data:
Weight of tup = 50 kN
Height of fall = 1 m
Area of piston = 0.2 m^2
Steam pressure on piston = 900 kN/m^2
Weight of anvil and frame = 1000 kN
Safe bearing capacity under static loading conditions = 200 kN/m^2
Coefficient of elastic uniform compression of soil = 5 × 10^4 kN/m^3
Base area of anvil (base area of elastic pad also) = 5.5 m^2
Thickness of elastic pad = 0.60 m
Modulus of elasticity of the material of the pad = 5 × 10^5 kN/m^2
Coefficient of restitution = 0.5