770 Chapter 27
27.3 Standard Operating Levels and Line-Up Tones ....................................................
Irrespective of the type of meter employed, it should be pretty obvious that a meter is
entirely useless unless it is calibrated in relation to a particular signal level (think about it
if rulers had different centimeters marked on them!).
Three important line-up levels exist (see Figure 27.6 ):
PPM4 0 dBu 0.775 V rms, used by United Kingdom broadcasters.
0VU 4 dBu 1.23 V rms, used in commercial music sector.
0VU 10 dBV 316 mV rms, used in consumer and “ prosumer ” equipment.
Pro VU BBC
PPMPro
digital
meterSemi-pro
VU (dbV)Semi-pro
digital
meterSemi-pro
0 VU line-up
approx8 dBuBBC line-up
(PPM 4)Pro-audio
line-upUnrecorded
peaks to
14 dBuUnrecorded
peaks to
2 dBudBU18100 10 3
0 101234 180 30 10 3
0 18056 684 18Figure 27.6 : Standard levels compared.