770 Chapter 27
27.3 Standard Operating Levels and Line-Up Tones ....................................................
Irrespective of the type of meter employed, it should be pretty obvious that a meter is
entirely useless unless it is calibrated in relation to a particular signal level (think about it
if rulers had different centimeters marked on them!).
Three important line-up levels exist (see Figure 27.6 ):
PPM4 0 dBu 0.775 V rms, used by United Kingdom broadcasters.
0VU 4 dBu 1.23 V rms, used in commercial music sector.
0VU 10 dBV 316 mV rms, used in consumer and “ prosumer ” equipment.
Pro VU BBC
PPM
Pro
digital
meter
Semi-pro
VU (dbV)
Semi-pro
digital
meter
Semi-pro
0 VU line-up
approx8 dBu
BBC line-up
(PPM 4)
Pro-audio
line-up
Unrecorded
peaks to
14 dBu
Unrecorded
peaks to
2 dBu
dBU
18
10
0
10
3
0
10
1
2
3
4 18
0
30
10
3
0 18
0
5
6
6
8
4
18
Figure 27.6 : Standard levels compared.