Audio Engineering

(Barry) #1

840 Chapter 28


so that the time code-time and clock time remain in synchronization. Drop frame is
important in broadcast work, where actual program time is important.


28.10.4 User Bits


Within the time code word there is provision for the hours, minutes, seconds, frames, and
fi eld ID that we normally see and “ user bits, ” which can be set by the user for additional
identifi cation. Use of user bits varies with some organizations using them to identify
shoot dates or locations and others ignoring them completely.