Room Acoustics 867
The so-called live end dead end approach to control room design uses the aforementioned
techniques to create a refl ection-free zone, enabling sound to be heard directly from
the monitors with a distinct time gap before any room refl ections arrive at the mixing
or prime listening position. Furthermore, such refl ections that do occur are carefully
controlled to ensure that they do not cause sound colorations nor affect the stereo image,
but just add an acoustic liveliness or low-level reverberant sound fi eld, which acts to
reduce listening fatigue and provide better envelopment within the sound fi eld.
20
31 63 125 250
1/3 Octave band centre frequency (Hz)
Frequency (Hz)
500
50 100 200 500 1K 2 K 5 K 10 K 20 K
1K 2K 4K 8K 16K
10 dB
5dB
Figure 29.14 : Frequency response plot of a monitor loudspeaker mounted adjacent to wall.