In the following we shall examine the transient-response characteristics of the compensated
system. (The gain-adjusted but uncompensated system is unstable.) The closed-loop transfer func-
tion of the compensated system isThe unit-step and unit-ramp response curves obtained with MATLAB are shown in Figures 7–113
and 7–114, respectively.C(s)
R(s)=
95.381s^2 +81s+ 10
4.7691s^5 +47.7287s^4 +110.3026s^3 +163.724s^2 +82s+ 10516 Chapter 7 / Control Systems Analysis and Design by the Frequency-Response MethodOutput1.60.6011.40.40.21.20.8t Sec042 6 8 10 12 14 16 18 20Unit-Step Response of Compensated SystemFigure 7–113
Unit-step response of
the compensated
system (Example
7–28).Output20801218421610146t Sec042 6 8 10 12 14 16 18 20Unit-Ramp Response of Compensated SystemFigure 7–114
Unit-ramp response
of the compensated
system (Example