582 Chapter 8 / PID Controllers and Modified PID Controllers

Output

c(

t)

t (sec)

Unit-Step Response of Compensated System
1.4

1.2

1

0.8

0.6

0.4

0.2

0
02468101214

Figure 8–17
Unit-step response
curve.

Unit-Ramp Input and Output

c(

t)

t (sec)

Unit-Ramp Response of Compensated System
20

18

16

14

12

10

8

6

4

2

0
02468101214161820

Compensated System

Figure 8–18
Unit-ramp input and
the output curve.

The resulting unit-step response curve is shown in Figure 8–17 and the unit-


ramp response curve in Figure 8–18. Notice that the closed-loop pole at s=0.1897


and the zero at s=0.2 produce a long tail of small amplitude in the unit-step


response.


For an additional example of design of a PID controller based on the frequency-


response approach, see Problem A–8–7.