586 Chapter 8 / PID Controllers and Modified PID ControllersAmplitudeTime (sec)Step Response
1.41.210.80.60.40.20
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5Figure 8–20
Unit-step response of
the system with
K=2.4anda=0.9.
(The maximum
overshoot is 9.23%.)To plot the unit-step response curve of the last set of the Kandavalues in the sorted table,
we enter the commandsK = sortsolution (k,1)
a = sortsolution (k,2)
and use the stepcommand. (The resulting unit-step response curve is shown in Figure 8–20.) To
plot the unit-step response curve with the smallest overshoot that is greater than 0%found in the
sorted table, enter the commandsK = sortsolution (11,1)
a = sortsolution (11,2)
and use the stepcommand. (The resulting unit-step response curve is shown in Figure 8–21.)AmplitudeTime (sec)Step Response1.21.410.80.60.40.20
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5Figure 8–21
Unit-step response of
the system with
K=2.8anda=0.7.
(The maximum
overshoot is 0.24%.)Openmirrors.com