Structural Design for Architecture
Fig. 6.48 Timber wallframe - platform frame type. In the
platform frame the individual wall and floor panels are
independent of each other. The sequence of construction
is that the ground-floor walls are erected first, followed by
the floors. These form a 'platform' on which the first-floor
walls are then erected. The system lends itself to prefabri-
cation and has the additional advantage that none of the
individual elements is of great length. Its disadvantage is
that the level of structural integrity is lower than with other
types of arrangement.
6.7.3 Timber wallframe structures
Timber wallframes are a type of loadbearing-
wall structure. They are sometimes called
simply timber frame structures but they are not
true skeleton frames. In wallframes, timber
wall-panels (stud panels) consisting of
elements of small cross-section placed at close
centres are used to support traditional forms
of roof and floor structure (Figs 6.48 to 6.51).
The overall size of the structure is usually
small: there are rarely more than two storeys
and floor spans are in the range 3.5 m to 5 m
with roof spans of around 6 m to 12 m. The
Fig. 6.49 Timber wallframe - balloon frame type. In the
balloon frame the studs which form the walls are continu-
ous through two floors and the floor joists are attached
directly to them. This arrangement provides better struc-
tural integrity than the platform frame and produces a
weathertight enclosure more quickly. It cannot be prefabri-
cated, however, and requires the use of very long timber
elements.
system is used principally for domestic
buildings.
The basic planning requirements for timber
wallframe buildings are the same as for all
loadbearing-wall structures. The wall plan,
which must be more-or-less the same on every
storey, must be capable of supporting all areas
of roof and floor and, as both the floor and
roof structures are one-way-spanning systems,
this requires an arrangement of primary
loadbearing walls which are parallel to each
other and spaced at roughly equal distances
222 apart. Atypical arrangement is shown in
Head binder.
Head plate
Floor joists
Boarding
-Sole plate
Studs
Boarding
Sole plate
Base wall
Header
Header
Head plate
Head binder
Floor joists:
Cill plate
Head binder
Head plate
Floor joists
Cavity barrier
Ledger
Cavity barrier
Floor joists
Sole plate
Base plate
Cill plate
Plywood
subfloor
Studs
Plywood
subfloor