Handbook of Civil Engineering Calculations

(singke) #1

LOSS OF HEAD CAUSED BY SUDDEN


ENLARGEMENT OF PIPE


Water flows through a pipe at 4 ft
3
/s (113.249 L/s). Compute the loss of head resulting
from a change in pipe size if (a) the pipe diameter increases abruptly from 6 to 10 in
(152.4 to 254.0 mm); (b) the pipe diameter increases abruptly from 6 to 8 in (152.4 to
203.2 mm) at one section and then from 8 to 10 in (203.2 to 254.0 mm) at a section farther
downstream.


Calculation Procedure:



  1. Evaluate the pressure-head differential required to decelerate
    the liquid
    Where there is an abrupt increase in pipe size, the liquid must be decelerated upon enter-
    ing the larger pipe, since the fluid velocity varies inversely with area. Let subscript 1 refer
    to a section immediately downstream of the enlargement, where the higher velocity pre-
    vails, and let subscript 2 refer to a section farther downstream, where deceleration has
    been completed. Disregard the frictional loss.
    Using Eq. 11 we seep 2 /w ^p 1 Iw+ (V 1 V 2 - V%)/g.

  2. Combine the result of step 1 with Eq. 9
    The result is Borda's formula for the head loss hE caused by sudden enlargement of the
    pipe cross section:


, (^i-K 2 )


2


*'° 2 g (23)

As this investigation shows, only part of the drop in velocity head is accounted for by
a gain in pressure head. The remaining head hE is dissipated through the formation of
eddy currents at the entrance to the larger pipe.



  1. Compute the velocity in each pipe
    Thus


Pipe diam, in (mm) Pipe area, ft^2 (m^2 ) Fluid velocity, ft/s (cm/s)
6(152.4) 0.196(0.0182) 20.4(621.79)
8 (203.2) 0.349 (0.0324) 11.5 (350.52)
10 (254.0) 0.545 (0.0506) 7.3 (222.50)


  1. Find the head loss for part a
    Thus, hE = (20.4 - 7.3)^2 /64.4 = 2.66 ft (81.077 cm).

  2. Find the head loss for part b
    Thus, HE = [(20.4 - 11.5)^2 + (11.5- 7.3)^2 ]/64.4 = 1.50 ft (45.72 cm). Comparison of these
    results indicates that the eddy-current loss is attenuated if the increase in pipe size occurs
    in steps.

Free download pdf