GPM
FIGURE 15. Pump characteristic curves for use in series installation.
Calculation Procedure:
- Plot the characteristic curves for the pumps being
considered
Figure 16 shows the characteristic curves for the proposed pumps. Point 1 in Fig. 15 is the
proposed operating head and flow rate. An alternative pump choice is shown at Point 2 in
Fig. 15. If two of the smaller pumps requiring only 0.25 hp (0.19 kW) each are placed in
series, they can generate the required 26-ft (7.9-m) head.
HEAD
- FEET