FIGURE 9. Sludge handling system.
generally located so as to have a suction head as shown in Fig. 9. A schematic of a rotary
lobe pump is shown in Fig. 10.
The required flow rate for the sludge pump using the 4 h/d, 7 d/wk operation scheme
is:
6,230 gal/day
Flow rate (gal/min) = (4 ^ 60 ^ - 26 ga./min (1.64 L/s)
- Compute the headless in the piping system
The head loss through the piping system is calculated using the Hazen-Williams formula:
/ 100 \i.85/ Q
185
\i L \
tf=(0.2083)( —) (^-)(-M)
where H = Dynamic head loss for clean water, ft (m)
C = Hazen-Williams constant (use 100)
Q = Flow rate in pipe, gal/min (L/s)
D = Pipe diameter, in (mm)
L = Equivalent length of pipe, ft (m)
Note: There is an SI version of the Hazen-Williams formula; use it for SI calculations.
DISCHARGE
SUCTION
FIGURE 10. Rotary-lobe pump schematic.
Aerobic
Digester
Rotary Lobe
Sludge Pump
Sludge
Holding
Tank
Sludge Dewatering
Facility (Centrifuge)
To Off Site
Disposal
3" Pipe
10 feet (3m)