FIGURE 9. Sludge handling system.

generally located so as to have a suction head as shown in Fig. 9. A schematic of a rotary
lobe pump is shown in Fig. 10.
The required flow rate for the sludge pump using the 4 h/d, 7 d/wk operation scheme
is:


6,230 gal/day
Flow rate (gal/min) = (4 ^ 60 ^ - 26 ga./min (1.64 L/s)


  1. Compute the headless in the piping system
    The head loss through the piping system is calculated using the Hazen-Williams formula:


/ 100 \i.85/ Q
185
\i L \
tf=(0.2083)( —) (^-)(-M)

where H = Dynamic head loss for clean water, ft (m)
C = Hazen-Williams constant (use 100)
Q = Flow rate in pipe, gal/min (L/s)
D = Pipe diameter, in (mm)
L = Equivalent length of pipe, ft (m)


Note: There is an SI version of the Hazen-Williams formula; use it for SI calculations.


DISCHARGE


SUCTION


FIGURE 10. Rotary-lobe pump schematic.

Aerobic
Digester

Rotary Lobe
Sludge Pump

Sludge
Holding
Tank

Sludge Dewatering
Facility (Centrifuge)

To Off Site
Disposal

3" Pipe

10 feet (3m)