Handbook of Civil Engineering Calculations

(singke) #1
FIGURE 12. Pump performance curve (A If a Laval Pumps, Inc.)

TDH was calculated above to be 26 lb/in^2 (179.1 kPa); Sf= (25 gal/100 revs)(0.757) + 3 =
21.925.


  1. Determine the pump horsepower
    The viscosity of a sewage sludge is dependent upon the percent solids and may be found
    using Table 3.
    Using Table 3, a 5 percent solids sludge has a viscosity of 1,050 cp. Therefore:


Nf= 2.2 Vl,050 cp = 22.36

Using the values outlined above, the motor horsepower is calculated:

HP 175 rpm r (175 rpm)(21.925) (25)(22.36) 1



  • -iir K


043
*

25 gai/io
°

revs)(26 psi)+
id*—-

+
^u

2
I

= 1.3hp(0.97kW)

The resulting horsepower of 1.3 hp (0.97 kW) is at best an informed estimate of the horse-
power which will be absorbed at the pump shaft during pumping. It includes no service
factor or margin for error, neither does it allow for inefficiency in power transmission sys-
tems.

Speed -RPM

Test Medium:
top

Displacement:
U.S. gal/1 OO rev
25

Port Size:
3 inches
(76.2 mm)

U.S. GPM (m CAPACITY
3
/hr)

Free download pdf