Skill Checklists for Taylor's Clinical Nursing Skills: A Nursing Process Approach

(Chris Devlin) #1

322


Copyright © 2011 by Wolters Kluwer Health | Lippincott Williams & Wilkins. Skill Checklists for Taylor's Clinical Nursing Skills:


Skill Checklists for Taylor's Clinical Nursing Skills:
A Nursing Process Approach, 3rd edition


Name Date


Unit Position


Instructor/Evaluator: Position


SKILL 15-2

Changing an IV Solution Container and
Administration Set

Goal:The prescribed IV infusion continues without interruption
and with infusion complications identified. Comments


  1. Verify IV solution order on MAR/CMAR with the medical
    order. Clarify any inconsistencies. Check the patient’s chart
    for allergies. Check for color, leaking, and expiration date.
    Know the purpose of the IV administration and medications
    if ordered.

  2. Gather all equipment and bring to bedside.

  3. Perform hand hygiene and put on PPE, if indicated.

  4. Identify the patient.

  5. Close curtains around bed and close the door to the room,
    if possible. Explain what you are going to do and why you
    are going to do it to the patient. Ask the patient about
    allergies to medications or tape, as appropriate.

  6. Compare IV container label with the MAR/CMAR.
    Remove IV bag from outer wrapper, if indicated. Check
    expiration dates. Scan bar code on container, if necessary.
    Compare patient identification band with the MAR/
    CMAR. Alternately, label solution container with the
    patient’s name, solution type, additives, date, and time.
    Complete a time strip for the infusion and apply to IV
    container.

  7. Maintain aseptic technique when opening sterile packages
    and IV solution. Remove administration set from package.
    Apply label to tubing reflecting the day/date for next set
    change, per facility guidelines.


To Change IV Solution Container


  1. If using an electronic infusion device, pause the device or
    put on “hold.” Close the slide clamp on the administration
    set closest to the drip chamber. If using gravity infusion,
    close the roller clamp on the administration set.

  2. Carefully remove the cap on the entry site of the new IV
    solution container and expose the entry site, taking care
    not to touch the exposed entry site.

  3. Lift empty container off IV pole and invert it. Quickly
    remove the spike from the old IV container,being careful
    not to contaminate it.Discard old IV container.


ExcellentSatisfactoryNeeds Practice
Free download pdf