SECTION 07550
MODIFIED BITUMEN MEMBRANE ROOFING (SBS)
Modified Bitumen Membrane Roofing (SBS)
UIHC #20X-0XX 07550-3
- Roof Plan and Details: By submittal of a bid for this project, the Contractor certifies
that the project plans and specifications have been reviewed, and that the proposed
roof system will be installed in accordance with these plans and specifications. If,
after award of contract and upon review of existing field conditions, the Contractor
wishes to modify the roof plans and/or details, the proposed change shall be submitted
as a shop drawing for review by the Architect/Engineer. - Roof Insulation: Reference Section 07220 - Roof and Deck Insulation for
requirements. - Sheet Metal Fabrication: Reference Section 07620 - Sheet Metal Flashing and Trim
for requirements.
G. Samples:
- Provide samples listed below, if specifically requested by the Architect/Engineer.
a. Surface membrane.
b. Base ply membrane.
c. Flashing membrane.
d. Mineral granules.
e. Other membranes specified.
H. Manufacturer's Field Services and Reports:
- Reference Section 01450 - Quality Control for requirements.
1.05 QUALITY ASSURANCE
A. Applicator shall be certified by manufacturer to install specified products.
B. The entire installation of roofing, insulation, flashing and sheet metal work shall be of the
quality required for acceptance by the membrane manufacturer to obtain the warranty
specified in this section.
C. Comply with the requirements of the regulatory agencies as specified herein.
D. As an approved applicator, all items required by the membrane manufacturer in the
installation of the manufacturer's system will be included in the work.
E. The roofing contractor shall assure that all roofing materials (i.e., membrane, insulation,
fasteners, asphalt, adhesives, sealants, etc.) are compatible with each other and the substrates
which they will be in contact with.
November 1, 2016