Architectural and Engineering Design Standards

(avery) #1

Rev. 13 November 1, 2016


Page |


4.11 Division 11 – Equipment for Roof Standards Update


11 24 23 Window Washing Systems


  1. Tie-off anchors shall be designed and installed on all new roofs per ANSI/IWCA I-14.1.

  2. A minimum of 10% of the tie-off anchors shall tested on site using load cell apparatus in accordance with
    manufacturer’s recommendations. Tests shall be conducted by an independent agency, and test reports shall be
    sent to the Owner.

  3. All anchors relying upon chemical adhesive fasteners are to be 100% tested on site using load cell apparatus in
    accordance with manufacturer’s recommendations. Tests shall be conducted by an independent agency, and test
    reports shall be sent to the Owner.


11 47 00 Ice Machines: Scottsman with dual filter system.

11 52 00 Audio-Visual Equipment


  1. Projectors: Contact Owner to discuss projectors and other related AV equipment.

  2. The designer shall utilize equipment racks for AV equipment.


11 52 13 Projection Screens: Manual screens shall be specified. Owner approval required for motorized.


  1. Manual with controlled screen return (CSR): Da-Lite Advantage or Draper.

  2. Tensioned concealed (recessed) ceiling mounted, motorized:
    a) Da-Lite Tensioned Advantage Electrol or Tensioned Avantage Deluxe Electrol.
    b) Draper Tensioned Access/Series V.
    c) Stuart – for high resolution and specialized viewing applications.


11 70 00 Healthcare Equipment


  1. Blanket Warming Cabinets: Coordinate selection with Owner.


4.12 Division 12 – Furnishings


12 24 13 Roller Shades


  1. Shades to be Mecho/5 or Slimline. Coordinate shade and fascia color with UIHC Design team.


12 30 00 Stainless Steel Casework / Storage Cabinets: CMP Continental Metal Products
12 35 53 Metal Casework Including Fume Hoods: Hamilton Industries or Owner approved equal
12 36 23 Solid Surface Countertops


  1. In wet areas solid surfaces shall be used.

  2. Sinks in solid surface counters shall be integral solid surface construction.

  3. Drip edges shall be used on all sides of patient room sinks.