178 CHEMISTRY AND TECHNOLOGY OF EXPLOSIVES
The authors explain that the strong steric effect on o- nitro groups produced
by the halogens, particularly iodine, is superposed upon the induction effect of
the o- nitro groups. Hence a reduction in the frequency of p- nitro group vibrations
occurs. This is in agreement with an observation by Golder and Zhdanov [37] who
TABLE 24
Substances
Asymmetrical Position of the
vibrations, cm-1 nitro group
sym-Trinitrobenzene 1558 o- and p-
1550
Picrylchloride 1560
p-
o-
1543
Picryl iodide 1558 p-o-
found that the C-N bond in the para position in picryl chloride is considerably
shortened (1.38 Å), and thus approaches the value of a double bond. The ortho-
situated C-N bonds are of a normal length (1.46 Å).
In the case of 2,4,6-trinitrobenzoic acid, the frequency of all the nitro groups
remains unchanged (1553 cm-1). However, the presence of nitro groups increases
the C=O frequency of the carboxylic group to 1733 cm-1 (as against 1698 cm-1
TABLE 25
SPECTRAL CHARACTERISTICS OF MONO-, DI- AND TRINITRO COMPOUNDS
Nitro compounds Bands, cm-1
o- Mononitro containing any one of the following groups ortho to the nitro:
CH 3 , C 2 H 5 , CHO, NH 2 , COOH
787-781
p- Mononitro containing the same group as above para to the nitro^1111
m- Dinitro containing the following additional group: CH 3 , C 2 H 5 , OH, 930-922†
NH-NH 2 , COOH, CHO. OCH 3 , CH 3 NH, C 2 H 5 NH, NO 2 (trinitro) in
sym-trinitro compounds 939-909
m- Dinitro containing other additional groups ortho to the nitro 840-836
sym-Trinitro which have the additional groups: CH 3 , C 2 H 5 , OH, OCH 3 ,
OC 2 H 5 , COOH, NH
† These bands are the most important for diagnostic purposes.
1081†