(lily) #1
4.8.3.1. Points to Remember


  • The .RFRQ and .DB files from the harmonic solution, and the .MODE,.EMAT,.LMODE,.ESAV, and
    .MLV files from the modal solution must be available.

  • The database must contain the same model for which the harmonic solution was calculated.


The procedure for the expansion pass follows:


4.8.3.2. Expanding the Modes


  1. Reenter the ANSYS solution processor.
    Command(s):/SOLU
    GUI: Main Menu> Solution


Note

You must explicitly leave SOLUTION (using the FINISH command) and reenter (/SOLU)
before performing the expansion pass.


  1. Activate the expansion pass and its options. ANSYS offers these options for the expansion pass:


Table 4.5: Expansion Pass Options

Com- GUI Path
mand

Option

Main Menu> Solution> Analysis Type> Expansion-
Pass

Expansion Pass On/Off EXPASS

Main Menu> Solution> Load Step Opts> Expansion-
Pass> Single Expand> Range of Solu's

No. of Solutions to Expand NUMEXP

Main Menu> Solution> Load Step Opts> Expansion-
Pass> Singe Expand> By Time Freq

Single Solution to Expand EXPSOL

Main Menu> Solution> Load Step Opts> Expansion-
Pass> Singe Expand> Range of Solu's

Phase Angle for Expansion HREXP

Main Menu> Solution> Analysis Type> Analysis
Options

Nodal Solution Listing HROUT
Format

Each of these options is explained in detail below.


  • Option: Expansion Pass On/Off (EXPASS)


Choose ON.


  • Option: Number of Solutions to Expand (NUMEXP,NUM)


Specify the number. This number of evenly spaced solutions will be expanded over a frequency
range (specified next). For example,NUMEXP,4,1000,2000 specifies four solutions in the frequency
range 1000 to 2000 (that is, expanded solutions at 1250, 1500, 1750, and 2000).


  • Option: Single Solution to Expand (EXPSOL)


Release 15.0 - © SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information