Handbook of Meat Processing

(Greg DeLong) #1

Process steps


Preventive Action


CCP


/CP


Critical limits


Monitoring


Corrective actions


Verifi


cation


Procedure

Frequency

Filling/vacuum

packaging

Preventive maintenance

of equipment, effective metal detection, visual inspection
Control of selling and

vacuum
GHP/GMP

CCP

0% metal particles

(ferric particles

≥ 2.5 mm;

non ferric particles

≥ 3.5 mm,

stainless steel particles

≥ 5 mm);

0% bones
0% fail of package seal, 0% fail of vacuum

Metal detection,

check, visual check
Visual check of

vacuum package
Selling test

On line On line

Reject product Notify maintenance,

Operators training
Stop line, replace

package and notify maintenance

Calibration of metal

detector,
Maintenance equipment

plan
Data record monitoring

analysis

Cooking

Correct time/

temperature

CCP

Internal

Temp = 68 – 70 ° C/20 min.
Temp = 70 ° C Time

≈ hours x kg of
meat
Or other according to

specifi

c technology

Measurement of

temperature and time

On line

Correction of

temperature and time. Reprocess.
Notify maintenance Reject product

Calibration of

thermometer
Maintenance equipment

plan
Data record monitoring

analysis

Cooling

Potable cooled water,

GHP, GMP
Correct time/

temperature
Rapid cooling to

temperatures

≤ 28 ° C

as soon as possible and hold to cool 24 h/0

± 1 ° C until

internal temperature of 2 ° C

CCP

Rapid cooling

Time

< 4 h

Rapid cooling Internal

Temp

≤ 28 ° C

Chill to

<^2

± 2 ° C in

refrigeration room at 0

± 1 ° C/24 h)
Or other according to

specifi

c technology

Measurement of

temperature and time

On line

Reprocess. Notify maintenance Segregation of

product and evaluation of its hygiene and safety
Reject product

Calibration of

thermometer
Maintenance equipment

plan
Data record monitoring

analysis

Unmolding

GHP, GMP Control of sealing and

vacuum packages
Visual check Recondition *

CP - GHP/

GMP

0% fail of package seal,

0% fail of vacuum

Visual check

100%

Recondition * Notify maintenance Operators training

Maintenance equipment

plan
Data record monitoring

analysis

(continued)

541