= 2.4E01B = 2.0
E010 = 1.0 B = 1.4E= x/1 EiiFigure 7.2: Influence function and corresponding values (JCSS [17]).
Sustained Load Transient Load
Category A 0
[m^2 ] qm[kN/m^2 ]V
[kN/m^2 ]U
[kN/m^2 ]1/(
[y]mp
[kN/m^2 ]V
[kN/m^2 ]1/
[y]dp[d]
Office 20 0.5 0.3 0.6 5 0.2 0.4 0.3 1 - 3
Lobby 20 0.2 0.15 0.3 10 0.4 0.6 1.0 1 – 3
Residence^20 0.3 0.15 0.3^7 0.3 0.4 1.0 1 – 3
Hotel guest
room20 0.3 0.05 0.1 10 0.2 0.4 0.1 1 – 3
Patient room 20 0.4 0.3 0.6 5 – 10 0.2 0.4 1.0 1 – 3
Laboratory 20 0.7 0.4 0.8 5 – 10
Libraries 20 1.7 0.5 1.0 >10
School
classroom100 0.6 0.15 0.4 >10 0.5 1.4 0.3 1 – 5Merchant
first floor
upper floor100
1000.9
0.90.6
0.61.6
1.61 – 5
1 – 50.4
0.41.1
1.11.0
1.01 – 14
1 – 14
Storage 100 3.5 2.5 6.9 0.1–1.0
Industrial:
light
heavy100
1001.0
3.01.0
1.52.8
4.15 – 10
5 – 10
Concentration
of people20 1.25 2.5 0.02 0.5Table 7.2: Parameters for live loads depending on the user category JCSS (2001).