O'CONNELLJP, GUILBAULTGG(2001b),Futuretrendsin Biosensorresearch',Anal.Lett., 34 , 1063±1078. PASINI P, POWARN, GUTIERREZ-OSUNAR, DAUNERTS, RODA A(2004),
Useof a gas-sensor
arrayfor detectingvolatileorganiccompounds(VOC)in chemicallyinduced
cells',Anal.Bioanal.Chem., 78 , 76±83.
PERSAUD K, DOODK(1982),Analysisof discriminationmechanismsin the mammalian olfactorysystemusinga modelnose',Nature, 299 , 352±355. RAMANATHANK, RANKM, SVITEL J, DZGOEVA, DANIELSSONB(1999),
Thedevelopmentand
applicationsof thermalbiosensorsfor bioprocessmonitoring',TrendsBiotechnol.,
12 , 499±505.
RAMSDEN JJ(1997),Opticalbiosensors',J. Mol.Recogn., 10 , 109±120. RAPPM, BO» ̊ B, VOIGTA, GEMMEKE H, ACHEHJ(1995),
Developmentof an analytical
microsystemfor organicgas detectionbasedon SAWresonators',FreseniusJ.
Anal.Chem., 352 , 699±704.
REYESDR,IOSSIFIDIS D, AUROUXPA,MANZA(2002),Micrototalanalysissystems.1.
Introduction,theory,and technology',Anal.Chem., 74 , 2623±2636.
RICHRL, MYSZKADG(2000),Surveyof the 1999surfaceplasmonresonancebiosensor literature',J. Mol.Recogn., 13 , 388±407. RICHRL,MYSZKADG(2001),
Surveyof the year 2000 commercialopticalbiosensor
literature',J. Mol.Recogn., 14 , 273±294.
RICHRL,MYSZKADG(2002),Surveyof the year 2001 commercialopticalbiosensor literature',J. Mol.Recogn., 15 , 352±376. RICHRL,MYSZKADG(2003),
Surveyof the year 2002 commercialopticalbiosensor
literature',J. Mol.Recogn., 16 , 351±382.
RODRIGUEZ-MOZAZ S, MARCOM P, DE ALDAM J L, BARCELOD(2004),Biosensorsfor environmentalapplications:futuredevelopmenttrends',PureAppl.Chem, 76 , 723±752. SAEVELSS, LAMMERTYNJ, BERNAAZ(2003),
Electronicnoseas a non-destructivetool to
evaluatethe optimalharvestdateof apples',PostharvestBiol.Tec., 30 , 3±14.
SCHALLERE, BOSSET JO, ESCHERF(1998),``Electronicnoses'' and theirapplicationto food',Lebensm.-Wiss.u.-Technol., 31 , 305±316. SCHELLERWF,RALISEV, MAKOWER A, PFEIFFER D(1990),
Amperometricbi-enzymebased
biosensorsfor the detectionof lactose± characterisationand application',J. Chem.
Tech.Biotechnol., 49 , 255±256.
SCHMIDTA, STANDFUSS-GABISCHC, BILITEWSKI U(1996),Microbialbiosensorfor free fattyacidsusingan oxygenelectrodebasedon thickfilmtechnology',Biosens. Bioelec., 11 , 1139±1145. SHEEHANAD, QUINNJ, DALYS, DILLONP, O'KENNEDY R(2003),
Thedevelopmentof novel
miniaturizedimmuno-sensingdevices:a reviewof a smalltechnologywitha large
future',Anal.Lett., 36 , 511±537.
STETTERJ R, PENROSEW R(2002),Understandingchemicalsensorsand chemicalsensor arrays(electronicnoses):past,present,and future',SensorsUpdate, 10 , 189±229. STRIKE DJ, MEIJERINKMGH,KOUDELKA-HEPM(1999),
Electronicnoses± a mini-review',
FreseniusJ. Anal.Chem., 364 , 499±505.
TOMIC O, ULMERH, HAUGENJE(2002),Standardisationmethodsfor handlinginstrument relatedsignalshiftin gas-sensorarraymeasurementdata',Anal.Chim.Acta, 472 , 99±111. TOMIC O, EKLO»V T, KVAALK, HAUGENJE(2004),
Recalibrationof a gas-sensorarray
systemrelatedto sensorreplacement',Anal.Chim.Acta, 512 , 199±206.
304 Handbookof hygiene controlin the foodindustry