332 CHEMICAL ENGINEERING VOLUME 1 SOLUTIONS
Temperature (K) Vapour pressure of n-butanolkN/m^2
330 5.99
335 7.89
340 10.36
345 14.97
350 17.50
Solution
See Volume 1, Example 13.10
PROBLEM 13.14
Estimate the height and base diameter of a natural draught hyperbolic cooling tower which
will handle 5000 kg/s water entering at 300 K and leaving at 294 K. The dry-bulb air
temperature is 287 K and the ambient wet-bulb temperature is 284 K.
Solution
See Volume 1, Example 13.8