Mechanical APDL Basic Analysis Guide

(Axel Boer) #1
What Commands Are
Related to This Tab?

Solution Con- What Does This Tab Let You Do?
trols Dialog
Box Tab
Choose time integration meth-
od.
Define integration parameters.
Sol'n Options Specify the type of equation EQSLV,RESCONTROL,
solver that you want to use.
Specify parameters for perform-
ing a multiframe restart.
Specify configuration details for
distributed solvers
LNSRCH,PRED,NEQIT,
RATE,CUTCONTROL,
CNVTOL

Nonlinear Control nonlinear options, such
as line search and solution
predictor.
Specify the maximum number
of iterations that are allowed
per substep.
Indicate whether you want to
include creep calculation in the
analysis.
Control bisections.
Set convergence criteria.
NCNV,ARCLEN,
ARCTRM

Advanced NL Specify analysis termination
criteria.
Control activation and termina-
tion of the arc-length method.

Once you are satisfied with the settings on the Basic tab, you do not need to progress through the
remaining tabs unless you want to change some of the advanced controls. As soon as you click OK on
any tab of the dialog box, the settings are applied to the database and the dialog box closes.


Note

Whether you make changes to only one or to multiple tabbed pages, your changes are applied
to the database only when you click OK to close the dialog box.

5.4.3. Accessing More Information


Discussions of the Solution Controls dialog box are included throughout this documentation as applicable.


For additional information, refer to the following:



  • Online help for the Solution Controls dialog box

  • Structural Static Analysis in the Structural Analysis Guide

  • Transient Dynamic Analysis in the Structural Analysis Guide

  • Nonlinear Structural Analysis in the Structural Analysis Guide


Release 15.0 - © SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information

Using Special Solution Controls for Certain Types of Structural Analyses