To transfer all solid model boundary conditions, use:
Command(s):SBCTRAN
GUI: Main Menu> Preprocessor> Loads> Define Loads> Operate> Transfer to FE> All Solid Lds
Main Menu> Solution> Define Loads> Operate> Transfer to FE> All Solid Lds
2.5.7. Surface Loads
The following table shows surface loads available in each discipline and their corresponding labels:
Table 2.5: Surface Loads Available in Each Discipline
Discipline Surface Load Label
Structural Pressure PRES[ 1 ]
Thermal Convection CONV
Heat Flux HFLUX
Infinite Surface INF
Magnetic Maxwell Surface MXWF
Infinite Surface INF
Electric Maxwell Surface MXWF
Surface Charge CHRGS
Density INF
Infinite Surface
Fluid Fluid-Structure In- FSI
terface IMPD
Impedance
All Superelement Load SELV
Vector
Diffusion Diffusion Load DFLUX
Acoustic FSI fluid-structure interaction flag
IMPD impedance or admittance coefficient
SHLD surface normal velocity or acceleration
Maxwell surface flag or equivalent source
surface
MXWF
FREE
INF free surface flag
PORT exterior Robin radiation boundary flag
ATTN Port number
BLI Absorption coefficient
Viscous-thermal boundary layer surface flag
- Do not confuse this with the PRES degree of freedom
The following table shows the commands to apply, list, and delete surface loads. You can apply them
at nodes and elements, as well as at lines and areas.
Table 2.6: Commands for Applying Surface Loads
Location Basic Commands Additional Commands
SFSCALE,SFCUM,SFFUN,SF-
GRAD
Nodes SF,SFLIST,SFDELE
Elements SFE,SFELIST,SFEDELE SFBEAM,SFFUN,SFGRAD
Release 15.0 - © SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
Loading