References
- D. Hoa, A.G. Kirk, M. Tabrizian, Towards integrated and sensitive surface plasmon resonance
biosensors: a review of recent progress. Biosens. Bioelectron. 23 (2), 151–160 (2007). (Review
paper) - X. Fan, I.M. White, S.I. Shopova, H. Zhu, J.D. Suter, Y. Sun, Sensitive optical biosensors for
unlabeled targets: A review. Anal. Chim. Acta 620 ,8–26 (2008). (Review paper) - G. Keiser, F. Xiong, Y. Cui, P.P. Shum, Review of diverse opticalfibers used in biomedical
research and clinical practice. J. Biomed. Optics 19 , art. 080902 (2014) (Review paper) - L.C.L. Chin, W.M. Whelan, I.A. Vitkin, Opticalfiber sensors for biomedical applications
(Chap. 17), inOptical-Thermal Response of Laser-Irradiated Tissue, 2nd edn., ed. by A.
J. Welch, M.J.C. van Gemert (Springer, New York, 2011) - X.D. Fan, I.M. White, Optofluidic microsystems for chemical and biological analysis. Nat.
Photonics 5 (10), 591–597 (2011). (Biosensors review paper) - F. Taffoni, D. Formica, P. Saccomandi, G. Di Pino, E. Schena, Optical fiber-based
MR-compatible sensors for medical applications: an overview. Sensors 13 , 14105– 14120
(2013). (Review paper) - X.D. Wang, O.F. Wolfbeis, Review:fiber-optic chemical sensors and biosensors (2008–2012).
Anal. Chem. 85 (2), 487–508 (2013). (Review paper) - O. Tokel, F. Inci, U. Demirci, Advances in plasmonic technologies for point of care
applications. Chem. Rev. 114 , 5728–5752 (2014). (Biosensors review paper) - T.J. Pfefer, K.T. Schomacker, M.N. Ediger, N.S. Nishioka, Multiple-fiber probe design for
fluorescence spectroscopy in tissue. Appl. Opt. 41 (22), 4712–4721 (2002) - P.R. Bargo, S.A. Prahl, S.L. Jacques, Optical properties effects upon the collection efficiency
of opticalfibers in different probe configurations. IEEE J. Sel. Topics Quantum Electron. 9 (2),
314 – 321 (2003) - U. Utzinger, R.R. Richards-Kortum, Fiber optic probes for biomedical optical spectroscopy.
J. Biomed. Opt. 8 , 121–147 (2003). (Review paper) - L. Wang, H.Y. Choi, Y. Jung, B.H. Lee, K.T. Kim, Optical probe based on double-clad optical
fiber forfluorescence spectroscopy. Opt. Express 15 (26), 17681–17689 (2007) - G.K. Bhowmick, N. Gautam, L.M. Gantayet, Design optimization offiber optic probes for
remotefluorescence spectroscopy. Opt. Commun. 282 (14), 2676–2684 (2009) - R.A. McLaughlin, D.D. Sampson, Clinical applications offiber-optic probes in optical
coherence tomography. Opt. Fiber Technol. 16 (6), 467–475 (2010). (Review paper) - R. Pashaie, Single opticalfiber probe forfluorescence detection and optogenetic stimulation.
IEEE Trans. Biomed. Eng. 60 , 268–280 (2013) - P. Svenmarker, C.T. Xu, S. Andersson-Engels, J. Krohn, Effects of probe geometry on
transscleral diffuse optical spectroscopy. Biomed. Opt. Express 2 , 3058–3071 (2011) - P. Gregorčič, M. Jezeršek, J. Možina, Optodynamic energy-conversion efficiency during an
Er:YAG-laser-pulse delivery into a liquid through differentfiber-tip geometries. J. Biomed.
Opt. 17 , article 075006 (2012) - D. Lorenser, B.C. Quirk, M. Auger, W.J. Madore, R.W. Kirk, N. Godbout, D.D. Sampson, C.
Boudoux, R.A. McLaughlin, Dual-modality needle probe for combinedfluorescence imaging
and three-dimensional optical coherence tomography. Opt. Lett. 38 (3), 266–268 (2013) - I. Latka, S. Dochow, C. Krafft, B. Dietzek, J. Popp, Fiber optic probes for linear and nonlinear
Raman applications—current trends and future development. Laser Photon. Rev. 7 (5), 698–
731 (2013). (Review paper) - A.J. Gomes, V. Backman, Algorithm for automated selection of application-specific
fiber-optic reflectance probes. J. Biomed. Opt. 18 , article 027012 (2013) - C.R. Wilson, L.A. Hardy, J.D. Kennedy, P.B. Irby, M.N. Fried, Miniature ball-tip optical
fibers for use in thuliumfiber laser ablation of kidney stones. J. Biomed. Opt. 21 (1), article
018003 (2016)