- U. Utzinger, Fiber optic probe design (Chap. 7), inBiomedical Photonics Handbook; Vol 1;
Fundamentals, Devices, and Techniques, 2nd edn., ed. by T. Vo-Dinh (CRC Press, Boca
Raton, 2014), pp. 253– 279 - D.V. Lim, Detection of microorganisms and toxins with evanescent wave fiber-optic
biosensors. Proc. IEEE 91 (6), 902–907 (2003) - A. Leung, P.M. Shankar, R. Mutharasan, A review offiber-optic biosensors. Sensors and
Actuators B 125 , 688–703 (2007). (Review paper) - R.M. Lequin, Enzyme immunoassay (EIA)/enzyme-linked immunosorbent assay (ELISA).
J. Clin. Chem. 51 (12), 2415–2418 (2005) - S.D. Gan, K.R. Patel, Enzyme immunoassay and enzyme-linked immunosorbent assay.
J. Invest. Dermatol. 133 (9), article 287 (2013) - P. Roriz, O. Frazão, A.B. Lobo-Ribeiro, J.L. Santos, J.A. Simões, Review offiber-optic
pressure sensors for biomedical and biomechanical applications. J. Biomed. Opt. 18 (5), article
050903 (2013) (Review paper) - G. Keiser,Optical Fiber Communications(Chap. 5) (McGraw-Hill, New York), 4th US edn.,
2011; 5th international edn. 2015 - N. Lagakos, J.H. Cole, J.A. Bucaro, Microbendfiber-optic sensor. Appl. Opt. 26 (11), 2171–
2180 (1987) - Z. Chen, D. Lau, J.T. Teo, S.H. Ng, X. Yang, P.L. Kei, Simultaneous measurement of
breathing rate and heart rate using a microbend multimodefiber optic sensor. J. Biomed. Opt.
19 , article 057001 (2014) - M. Karimi, T. Sun, K.T.V. Grattan, Design evaluation of a high birefringence single mode
opticalfiber-based sensor for lateral pressure monitoring applications. IEEE Sens. J. 13 (11),
4459 – 4464 (2013) - B.H. Lee, Y.H. Kim, K.S. Park, J.B. Eom, M.J. Kim, B.S. Rho, H.Y. Choi, Interferometric
fiber optic sensors. Sensors 12 (3), 2467–2486 (2012) - R. Yang, Y.S. Yu, X. Yang, C. Chen, Q.D. Chen, H.B. Sun, Single S-taperedfiber
Mach-Zehnder interferometers. Opt. Lett. 36 (33), 4482–4484 (2011) - Z.B. Tian, S.S.-H. Yam, J. Barnes, W. Bock, P. Greig, J.M. Fraser, H.P. Loock, R.D.
Oleschuk, Refractive index sensing with Mach-Zehnder interferometer based on concatenating
two single-modefiber tapers. IEEE Photon. Technol. Lett. 20 (8), 626–628 (2008) - L. Jiang, L. Zhao, S. Wang, J. Yang, H. Xiao, Femtosecond laser fabricated all-opticalfiber
sensors with ultrahigh refractive index sensitivity: modeling and experiment. Opt. Express 19 ,
17591 – 17598 (2011) - C.R. Liao, Y. Wang, D.N. Wang, M.W. Yang, Fiber in-line Mach-Zehnder interferometer
embedded in FBG for simultaneous refractive index and temperature measurement. IEEE
Photon. Technol. Lett. 22 (22), 1686–1688 (2010) - Y. Jung, S. Lee, B.H. Lee, K. Oh, Ultracompact in-line broadband Mach-Zehnder
interferometer using a composite leaky hollow-optical-fiber waveguide. Opt. Lett. 33 (24),
2934 – 2936 (2008) - W.J. Bock, T.A. Eftimov, P. Mikulic, J. Chen, An inline core-cladding intermodal
interferometer using a photonic crystalfiber. J. Lightw. Technol. 27 (17), 3933–3939 (2009) - L.C. Li, L. Xia, Z.H. Xie, D.M. Liu, All-fiber Mach-Zehnder interferometers for sensing
applications. Opt. Express 20 (10), 11109–11120 (2012) - K.S. Chiang, F.Y.M. Chan, M.N. Ng, Analysis of two parallel long-periodfiber gratings.
J. Lightw. Technol. 22 (5), 1358–1366 (2004) - D.J.J. Hu, J.L. Lim, M. Jiang, Y. Wang, F. Luan, P.P. Shum, H. Wei, W. Tong, Long period
grating cascaded to photonic crystalfiber modal interferometer for simultaneous measurement
of temperature and refractive index. Opt. Lett. 37 (12), 2283–2285 (2012) - L. Marques, F.U. Hernandez, S.W. James, S.P. Morgan, M. Clark, R.P. Tatam, S. Korposh,
Highly sensitive opticalfibre long period grating biosensor anchored with silica core gold shell
nanoparticles. Biosens. Bioelectron. 75 , 222–231 (2016)
230 7 Optical Probes and Biosensors