Fig. 5.16 Interface between electronics and in vivo regenerative neural tissue.aProjection of
30 μm thick volume of slice shows the interface between electronics in in vivo with subventricular
zone (I) and 3D render of red dashed box highlighted zoomed-in region (II).bProjection of 30μm
thick volume of slice shows the interface between electronics in in vivo with staria (I) and 3D
render of red dashed box highlights zoomed-in region (II). Blue: DAPI, green: SU-8 and NeuN
and red: GFAP.cControl sample shows subventricular zone without device.dProjection of
80 μm thick volume for the region highlighted by white box in Fig.5.15g. Blue: DAPI, green:
SU-8 ribbon and neurons and red: GFAP


90 5 Syringe Injectable Electronics