(d) Subtract the mean background intensity from the mean
spot intensity to obtain the intensity of a single SunTag
protein.
- Measure GFP intensity of a translation site.
(a) Draw a ROI (of the same size as used for measuring single
mature proteins) around each translation site.
(b) Measure the average fluorescence intensity of each trans-
lation site.
(c) Subtract the mean background intensity (measured in
step 1c) from the mean translation site intensity to calcu-
late the mean intensity of a translation site. - In experiments where substantial photobleaching is observed,
correction for photobleaching of the fluorescence intensities is
critical (see Note 17 for further discussion about
photobleaching). - Divide the mean GFP intensity of the translation sites by the
mean intensity of the single mature SunTag proteins. - The value calculated instep 4 provides an estimate of the
number of SunTag arrays present at a translation site (see
Note 18and Fig.4 for a further description on how to inter-
pret GFP intensity).
3.6.2 Image Analysis
Software to Measure GFP
Intensities
In order to analyze the images obtained by microscopy, different
image analysis software packages can be used, including Matlab,
Python, and ImageJ. The choice for a specific software package
mainly depends on the experimenter’s previous experience and
personal preference. For unique or complex questions, custom
analysis software may be required, making Matlab and Python
good options. However, for many simple types of analysis, existing
ImageJ plugins can be used. Currently, several plugins are available
which allow, for example, counting of the number of translation
spots per cell, measuring the intensities of individual translation
spots, or tracking translation spots over time. One simple ImageJ
plugin that is useful for the analysis of translation dynamics is the
spot_counter ImageJ plugin (http://fiji.sc/SpotCounter) devel-
oped by Nico Stuurman. This plugin counts the number of transla-
tion spots in a cell over time, and determines the fluorescence
intensity of individual spots.
4 Notes
- Choosing the gene of interest in the translation reporter. In
principle, any gene can be introduced in the translation
reporter, and the choice will mainly depend on the goal of
the experiment. However, it is important to take into account
396 Suzan Ruijtenberg et al.