acquisition, visualization, and analysis. Prote-
omics 17(3–4):1600267. https://doi.org/
10.1002/pmic.201600267
- Ledbetter JA, Rouse RV, Micklem HS, Her-
zenberg LA (1980) T cell subsets defined by
expression of Lyt-1,2,3 and Thy-1 antigens.
Two-parameter immunofluorescence and
cytotoxicity analysis with monoclonal antibo-
dies modifies current views. J Exp Med 152
(2):280–295
- Titus JA, Sharrow SO, Connolly JM, Segal
DM (1981) Fc (IgG) receptor distributions
in homogeneous and heterogeneous cell
populations by flow microfluorometry. Proc
Natl Acad Sci U S A 78(1):519–523
- Kavai M, Bodolay E, Szollosi J (1982) Char-
acterization of human monocyte subpopula-
tions by flow cytometry. Immunology 47
(2):255–262
- Poncelet P, Carayon P (1985) Cytofluoro-
metric quantification of cell-surface antigens
by indirect immunofluorescence using
monoclonal-antibodies. J Immunol Methods
85(1):65–74. https://doi.org/10.1016/
0022-1759(85)90274-1
- Christensen J, Leslie RG (1990) Quantitative
measurement of Fc receptor activity on
human peripheral blood monocytes and the
monocyte-like cell line, U937, by laser flow
cytometry. J Immunol Methods 132
(2):211–219. https://doi.org/10.1016/
0022-1759(90)90032-Q
- Plesner T, Hansen NE, Carlsen K (1990) Esti-
mation of PI-bound proteins on blood cells
from PNH patients by quantitative flow cyto-
metry. Br J Haematol 75(4):585–590
- Pallis M, Robins A, Powell R (1993) Quanti-
tative analysis of lymphocyte CD1 la using
standardized flow cytometry. Scand J Immu-
nol 38(6):559–564. https://doi.org/10.
1111/j.1365-3083.1993.tb03241.x
- Lavabre-Bertrand T, Janossy G, Ivory K,
Peters R, Secker-Walker L, Porwit-
MacDonald A (1994) Leukemia-associated
changes identified by quantitative flow cyto-
metry: I. CD10 expression. Cytometry 18
(4):209–217. https://doi.org/10.1002/
cyto.990180404
- Farahat N, Lens D, Zomas A, Morilla R,
Matutes E, Catovsky D (1995) Quantitative
flow cytometry can distinguish between nor-
mal and leukaemic B-cell precursors. Br J
Haematol 91(3):640–646
- Bikoue A, George F, Poncelet P, Mutin M,
Janossy G, Sampol J (1996) Quantitative
analysis of leukocyte membrane antigen
expression: normal adult values. Cytometry
26(2):137–147.https://doi.org/10.1002/(
SICI)1097-0320(19960615)26:2<137::
AID-CYTO7>3.0.CO;2-D
- Denny TN, Stein D, Mui T, Scolpino A, Hol-
land B (1996) Quantitative determination of
surface antibody binding capacities of
immune subsets present in peripheral blood
of healthy adult donors. Cytometry 26
(4):265–274. https://doi.org/10.1002/(
SICI)1097-0320(19961215)26:4<265::
AID-CYTO5>3.0.CO;2-B
- Ginaldi L, Farahat N, Matutes E, De
Martinis M, Morilla R, Catovsky D (1996)
Differential expression of T cell antigens in
normal peripheral blood lymphocytes: a quan-
titative analysis by flow cytometry. J Clin
Pathol 49(7):539–544
- Ginaldi L, Matutes E, Farahat N, De
Martinis M, Morilla R, Catovsky D (1996)
Differential expression of CD3 and CD7 in
T-cell malignancies: a quantitative study by
flow cytometry. Br J Haematol 93
(4):921–927
- Ginaldi L, De Martinis M, Matutes E,
Farahat N, Morilla R, Catovsky D (1998)
Levels of expression of CD19 and CD20 in
chronic B cell leukaemias. J Clin Pathol 51
(5):364–369
- Cabezudo E, Carrara P, Morilla R, Matutes E
(1999) Quantitative analysis of CD79b, CD5
and CD19 in mature B-cell lymphoprolifera-
tive disorders. Haematologica 84
(5):413–418
- D’Arena G, Musto P, Cascavilla N,
Dell’Olio M, Di Renzo N, Carotenuto M
(2000) Quantitative flow cytometry for the
differential diagnosis of leukemic B-cell
chronic lymphoproliferative disorders. Am J
Hematol 64(4):275–281
- Lopez-Matas M, Rodriguez-Justo M,
Morilla R, Catovsky D, Matutes E (2000)
Quantitative expression of CD23 and its
ligand CD21 in chronic lymphocytic leuke-
mia. Haematologica 85(11):1140–1145
- Rego EM, Garcia AB, Carneiro JJ, Falcao RP
(2001) Immunophenotype of normal and
leukemic bone marrow B-precursors in a Bra-
zilian population. A comparative analysis by
quantitative fluorescence cytometry. Braz J
Med Biol Res 34(2):183–194
- Gritzapis AD, Baxevanis CN, Missitzis I, Kat-
sanou ES, Alexis MN, Yotis J, Papamichail M
(2003) Quantitative fluorescence cytometric
measurement of estrogen and progesterone
receptors: correlation with the hormone bind-
ing assay. Breast Cancer Res Treat 80
(1):1–13. https://doi.org/10.1023/
A:1024462416640
Single-Cell Protein Assays: A Review 303