Beam: 14 .75 ft. (4.5 m)
Molded depth: 7 .58 ft. (2.31 m)
Length of longest compartment: 17 .6 ft.
(5.36 m)
Displacement: 25 .2 long tons (25.6 metric
tons)
CFR Commercial would require one
power-driven pump of 10 gpm (38 lpm) and
one portable hand pump, or one fixed hand
pump of 10 gpm (38 lpm) and one portable
pump of 5 gpm (19 lpm). Minimum bilge pipe
diameter is 1 inch (DN 25 mm).
ABS would require one power-driven
pump of 25 gpm (95 lpm) with the minimum
pipe diameter found by the ABS formulas,
but not less than Table 18-2: a 1-inch (DN
25 mm) ID pipe, in this case.
The main suction line for ABS would be
Inspecting the pipe tables in Appendix B, we
find that 1^1 / 2 - inch schedule 40 pipe has an ID
of 1. 61 inches. This is within^1 / 4 inch of the
calculated pipe ID. Use 1^1 / 2 - inch schedule 40
pipe.
Or
Inspecting the pipe tables in Appendix B, we
find that DN 40 mm schedule 40 pipe has an
ID of 40.89 mm. This is within 6 mm of the
calculated pipe ID. Use DN 40 mm schedule
40 pipe.
The ABS branch line for the longest com-
partment would be
Inspecting the pipe tables in Appendix B,
we find that 1^1 / 4 - inch schedule 40 pipe has
an ID of 1. 38 in. This is within^1 / 4 inch of the
calculated pipe ID. Use 1^1 / 4 - inch schedule
40 pipe.
Or
Inspecting the pipe tables in Appendix B, we
find that DN 32 mm schedule 40 pipe has an
ID of 35.05 mm. This is within 6 mm of the
calculated pipe ID. Use DN 32 mm schedule
40 pipe.
Note that smaller compartments could
use smaller branch-line diameters, but not
less than 1 inch (25 mm) ID for this vessel.
It’s usually best, however, to make all
branch lines the same diameter (the one
required for the largest compartment) to
simplify installation, maintenance, and
repair.
Bilge-Piping Material
CFR Commercial states that bilge and fire-
main piping are piping for vital systems. CFR
Commercial requires that all such piping be
steel or stainless steel. The exception is for
aluminum boats, which may use aluminum
pipe, schedule 80 wall minimum.
Estimating Flooding Rate
from Hull Damage
Both the CFR and ABS minimum recommen-
dations for bilge-pump capacity seem too low
1
17 .6ft.c ompa rtme nt le ng th
(14.75 ft.be
+
aam 7.58 ft.molded depth)
1,500
1. 51 in.ID
+
=
PART SIX: PLUMBING SYSTEMS WITH NOTES ON FIRE SUPPRESSION
25 2. 16
5 .36 m compartment length (4.5m
bea
+
mm2.31 m molded depth)
36 .7 8 mm ID
+
=
TABLE 18-2. ABS BILGE-SYSTEM REQUIREMENTS
Minimum Capacity Minimum Pipe
Vessel Length per Pump Inside Diameter
Below 65 ft. (19.8 m) 25 gpm (240 lpm) 1 in. (25 mm)
65 ft. (19.8 m) or 50 gpm (184 lpm) 1.25 in. (32 mm)
greater but less than
100 ft. (30.5 m)
100 ft. (30.5 m) or 66.6 gpm (240 lpm) 1.5 in. (38 mm)
greater but less than
150 ft (45.7 m)
1
46 ft.WL (14.75 ft.beam 7.58 ft.depth
+
+ mmolde d)
2,500
= 1. 64 in.ID
25 1++.68 14 m LOA (4.5 m beam 2.31 m depth mollded)
= 41 .4mmID