In these critical locations, glazing must satisfy one of the
following:-
Breakage to leave only a small opening with small detachable
particles without sharp edges.
Disintegrating glass must leave only small detached pieces.
Inherent robustness, e.g. polycarbonate composition. Annealed
glass acceptable but with the following limitations:-
Panes in small areas, <250 mm wide and <0.5 m^2 area. e.g.
leaded lights (4 mm annealed glass) and Georgian pattern
(6 mm annealed glass).
Protective screening as shown:
Thickness of Max. glazed area.
annealed glass (mm) Height (m) Width(m)
8 1„100 1„100
10 2„250 2„250
12 3„000 4„500
15 no limit
Glazing---Location