Building Construction Handbook, Eighth Edition

(Nancy Kaufman) #1
Conservation of Energy ~ this can be achieved in two ways:

1. Cold Deck † insulation is placed on the ceiling lining, between
joists. See page 448 for details. A metallized polyester lined
plasterboard ceiling functions as a vapour control layer, with
a minimum 50 mm air circulation space between insulation and
decking. The air space corresponds with eaves vents and both
provisions will prevent moisture build-up, condensation and
possible decay of timber.


  1. (a) Warm Deck † rigid* insulation is placed below the
    waterproof covering and above the roof decking. The insulation
    must be sufficient to maintain the vapour control layer and roof
    members at a temperature above dewpoint, as this type of roof
    does not require ventilation.


(b) Inverted Warm Deck † rigid* insulation is positioned above the
waterproof covering. The insulation must be unaffected by
water and capable of receiving a stone dressing or ceramic
pavings.

* Resin bonded mineral fibre roof boards, expanded polystyrene or
polyurethane slabs.

Typical Warm Deck Details ~

Timber Flat Roofs---Thermal Insulation