Typical examples of contemporary construction practice that
achieve a thermal transmittance or U-value below 0„30 W/m^2 K~


120 mm mineral
wool cavity batts 100 mm lightweight
concrete block inner
leaf

13 mm lightweight
plaster

102.5 mm external
brick outer leaf

75 mm mineral
wool cavity batts lightweight concrete
blocks, density
460 kg/m^3

9.5 mm plasterboard
on dabs
T

102.5 mm external
brick outer leaf

50 mm wide cavity

40 mm mineral wool
cavity batts

mineral wool batts

T

VCL and 12.5 mm
plasterboard

breather membrane
and sheathing
board

102.5 mm external
brick outer leaf

TIMBER FRAME PART CAVITY FILL, T = 100 mm U = 0.26 W/m^2 K
T = 120 mm U = 0.24 W/m^2 K
T = 140 mm U = 0 .21 W/m^2 K

FULL FILL CAVITY WALL, Block density 750 kg/m^3 U = 0.25 W/m^2 K
Block density 600 kg/m^3 U = 0.24 W/m^2 K
Block density 475 kg/m^3 U = 0.23 W/m^2 K

FULL FILL CAVITY WALL,
T = 150 mm U = 0.26 W/m^2 K
T = 200 mm U = 0.24 W/m^2 K

T = 125 mm U = 0.28 W/m^2 K

Note: Mineral wool insulating batts have a typical thermal
conductivity () value of 0„038 W/mK.