Building Construction Handbook, Eighth Edition

(Nancy Kaufman) #1
The tendency for a column to buckle depends on its slenderness as
determined by the ratio of its effective length to the radius of
gyration about the weaker axis.

Effective lengths of columns and struts in compression ~

L l = 0.7L

Position and direction fixed is location at specific points by
beams or other means of retention. Position fixed only means
hinged or pinned.

Position and
direction fixed
both ends Position and
direction fixed
at one end,
direction only
fixed at the
other end

Position
and
direction fixed
one end only

Position fixed
both ends,
direction fixed
at one end

Position
fixed
both ends

l = 0.85L l =L
l = 1.5L l = 2L

The effective lengths shown apply to the simplest of structures,
for example, single storey buildings. Where variations occur such as
cross braced support to columns, corrective factors should be
applied to the effective length calculations. This data is available
in BS 5950-1: Structural use of steelwork in building. Code of
practice for design. Rolled and welded sections.

End conditions Effective length relative
to actual length

Restrained both ends in position and
direction

0.70


Restrained both ends in position with one
end in direction

0.85


Restrained both ends in position but
not in direction

1.00


Restrained one end in position and
direction. The other end restrained
in direction only

1.50


Restrained one end in position and
direction. The other end unrestrained

2.00


Structural Steelwork -- Effective Column Length

Free download pdf