Plasterboard lining to stud framed partition walls satisfies the
Building Regulations, Approved Document B † Fire safety, as a
material of ``limited combustibility'' with a Class O rating for
surface spread of flame (Class O is better than Classes 1 to 4 as
determined by BS 476-7). The plasterboard dry walling should
completely protect any combustible timber components such as
sole plates. The following shows typical fire resistances as applied
to a metal stud frame ~
30 minute fire resistance75 mmHeight limit 2.500self drilling/self tapping screw fixingsmetal channel stud frame12.5 mm wallboardstaggered screw fixings2 Nƒ 12.5 (15) mm
wallboards60(90) minute fire resistance100 mm
(110)Height limit 3.400 (3.700)110 mm120 minute fire resistanceHeight limit
4.200 metal box stud frame2 Nƒ 15 mm
firecheck
plasterboardsFor plasterboard types see page 642.
Stud Partitions -- Fire Protection