84 ENVIRONMENTAL ENGINEERING


Microammeter

PI


Electrolyte
solution

0 ring


Membrane

A LL Lead anod>l
Silver cathode

Figure 5-1. Schematic diagram of a galvanic cell oxygen probe.

the electricity recorded is proportional to the concentration of oxygen in the electrolyte
solution.
In the commercial models, the electrodes are insulated from each other with non-
conducting plastic and are covered with a permeable membrane with a few drops of
electrolyte between the membrane and electrodes. The amount of oxygen that travels
through the membrane is proportional to the dissolved oxygen concentration. Dissolved
oxygen probes are convenient for fieldwork, but need careful maintenance and calibra-
tion (usually against Winkler results). Most oxygen probes are sensitive to changes in
temperature and have thermisters attached to the probe so that temperature adjustments
can be made in the field.

BIOCHEMICAL OXYGEN DEMAND

The rate of oxygen use is commonly referred to as biochemical oxygen demand (BOD).
Biochemical oxygen demand is not a specific pollutant, but rather a measure of the