Encyclopedia of Environmental Science and Engineering, Volume I and II

(Ben Green) #1

URBAN RUNOFF 1199


TABLE 25
DAF design parameters

Overflow Rate (gal/ft^2 /min)
Low rate 1.3–4.0
High rate 4.0–10.0

Horizontal Velocity (ft/min) 1.3–3.8

Detention Time (min)
Flotation cell range 10–60
Floating cell average 25
Saturation tank 1–3
Mixing chamber 1

Pressurized Flow (% of total flow)
Split-flow pressurization 20–30
Effluent recycle pressurization 25–45
Air to Pressurized Flow Ratio
(standard ft^3 /100 gal)

1.0

Air to Solids Ratio 0.05–0.35

Pressure in Saturation Tank (lb/in.^2 ) 40–70

Float
Volume (% of total flow) 0.75–1.4
Solids concentration (% dry weight basis) 1–2
lb/in.^2  0.0703  kg/m^2.
(EPA-600/8-77-014).

100

100
1 000

1 000

10 000

10 000

100 000

NOTE: 11^2 = 0.0626-m^3
Mgal/s = 0.0438-m^3 /s

DISSOLVED AIR FLOTATION TANK SURFACE AREA, ft^2

CONSTRUCTION COSTS, $ 1 000

ESTIMATED 90 Mgal/d PLANT.
MAINTANENCE VISC [b]

MACINE WIRE FACILITIES
INCLUDE PRETREATMENT [d]

DERIVED FROM
COST CURVE [c]

SAN FRANCISCO, CA [a]

FIGURE 14 DAF construction costs: ENR  2,000 (EPA/600/8-77-014).

TABLE 23
Percent removals achieved with screening/DAF (Milwaukee, WI)

Without chemical
flocculant addition

With chemical
flocculant addition
BOD 5 35  8 60  11
COD 41  8 57  11
SS 43  7 71  9
Volatile SS 48  11 71  9
Nitrogen 29  14 24  9

(EPA-600-77-069a).

TABLE 24
Percent removals achieved with screening/DAF (Racine)

Percent Removal

Site I Site II

BOD 5 57.5 65.4
TOC 51.2 64.7
SS 62.2 73.3
Volatile SS 66.8 70.9
Total Phosphorus 49.3 70.0

(EPA-600/2-79-106a).