VAPOR AND GASEOUS POLLUTANT FUNDAMENTALS 1219
For adsorption the particles are usually dumped into a
column as a packed bed (Figure 6). In commercial adsorp-
tion columns, equilibrium concentrations are not attained
uniformly, but for convenience the rate of adsorption is
assumed to be proportional to C. See below under Reaction.
The time t 3 in which breakthrough (Cig at the exit equals
the permissible set amount) occurs may be established by
analyzing the differential component mass balance assuming
that the transport of material again is governed by diffusion
through a film
N k C Ci g ig( ig)
*
(12)
in which Cig* is the gas phase concentration in equilibrium
with the absorbed concentration Cis at the same elevation.
GAS STREAM OUT
GAS STREAM IN
FILM
SOLIDPHASEGASPHASE
z 0 dz
L
z inlet
c)
a) b)
vz
vz
Co
C=C(t,z=z 0 )
t 4 >t 3 >t 2 >t 1
t 3 t 4
t 2
t 1
Cio
z 0
FIGURE 6 (a) Pictorial representation. (b) Schematic model showing a differential
element over which a mass balance is made. (c) Pollutant concentration as a function
of time at various heights.
1 2 3 4 5 6 7 8 9 10
1.0
c
c 0
SIMPLE LANGMUIR
DISSOCIATIVE
LANGMUIR
COMPETITIVE
LANGMUIR
K 1 C 1
FIGURE 5
C022_001_r03.indd 1219 11/18/2005 2:32:44 PM