822 PARTICULATE EMISSIONS
In addition to new source performance standards, major
new stationary sources and major modifications are usually
subject to a “Prevention of Significant Deterioration” review.
If a particulate source of more than 25 tons/year is located
in an area which attains NAAQS or is unclassifiable with
respects to particulates, the owner must demonstrate that the
source will not violate NAAQS or PSD concentration incre-
ments. This requires modelling and preconstruction moni-
toring of ambient air quality. If the new or expanded source
is to be located in an area which does not meet NAAQS, then
emission from other sources must be reduced to offset the
new source. The regulation regarding emission offsets and
prevention of significant deterioration are relatively recent.
A summary of federal regulations as of 1981 has recently
been published as a quick guide to this rapidly changing
field.^18
In recent years, regulation of particulate emissions from
mobile sources has been initiated. The burden is essentially
on manufacturers of diesel engines. Because the emission
requirements and test procedures are quite complex and
because the target is highly specific, a comprehensive discus-
sion is beyond the scope of this article. Some representative
standards are: Diesel engines for urban buses, 0.019 grams/
megajoule, and other diesel engines for road use, 0.037 grams/
megajoule:^19 Non-road diesel engines, 1 gram/kilowatt-hour
for sizes less than 8 kilowatts in tier 1 down to 0.2 grams/
kilowatt-hour for units larger than 560 kilowatts in tier 2.^20
Locomotives, 0.36 grams/bhp-hr for switching service in tier
1 down to 0.1 grams/bhp-hr for line service in tier 3.^21 Marine
diesel engines, 0.2 grams/KwH to 0.5 grams/KwH, depending
on displacement and tier.^22 Note that the emission units above
are as specified in the printed regulation.
Particulate emission standards are also being promulgated
by agencies other than the Environmental Protection Agency.
In general, these are workplace standards. An example
would be the standard for mobile diesel-powered transporta-
tion equipment promulgated by the Mine Safety and Health
Administration. This specifies that the exhaust “shall not con-
tain black smoke.”^23
MEASUREMENT OF PARTICULATE EMISSIONS
As a first step in any program for control of particulate emis-
sions, a determination must be made of the quantity and
nature of particles being emitted by the subject source. The
quantity of emissions determines the collection efficiency
and size of required cleanup equipment. The particle size and
chemical properties of the emitted dust strongly influence
the type of equipment to be used. Sampling for this purpose
has been mainly a matter of industrial concern. A last step
in most control programs consists of measuring pollutants
in the cleaned gas stream to ensure that cleanup equipment
being used actually permits the pertinent emission targets to
be met. With increasing public concern and legislation on air
pollution, sampling for this purpose is increasingly required
by statute to determine compliance with the pertinent emis-
sion regulations. To this end the local pollution control
authority may issue a comprehensive sampling manual
which sets forth in considerable detail the procedures to be
used in obtaining raw data and the computations involved in
calculating the pertinent emission levels.
Complete and comprehensive source testing procedures
are beyond the scope of this paper. References 24–28 give
detailed instruction for performance of such tests.
Sampling of gas streams, especially for particulates, is
simple only in concept. Actual measurement require special-
ized equipment, trained personnel, careful experimental and
computational techniques, and a considerable expenditure
of time and manpower. Matters of technique and equipment
are covered in source testing manuals as mentioned above
and are briefly summarized later in this paper. Two addi-
tional complicating factors are usually present. First is the
frequent inaccessibility of sampling points. These points are
often located in duct work 50–100 ft above ground level.
Scaffolding must often be installed around the points, and
several hundred pounds of equipment must be lifted to that
level. Probe clearances are often critical, for in order to make
a sample traverse on 12 ft dia. stack, a 14 ft probe is needed,
and clearance must be available for insertion into the sam-
pling port as well as a means for suspending the probe from
above. At least one professional stack sampler is an ama-
teur mountain climber and puts his hobby to good use on
the job. A second complicating factor is the adverse physical
conditions frequently encountered. A somewhat extreme but
illustrative example is a refinery stream recently sampled. Gas
temperature was 1200°F requiring special probes and gas-
kets and protective clothing for the workers. The gas stream
contained 10% carbon monoxide creating potential hazards
of poisoning and explosion especially since duct pressure
was slightly above that of the atmosphere. Temperature in
the work area was in excess of 120°F contributing further to
the difficulty of the job.
In preparation for a sampling program, work platforms
or scaffolding and valved sample ports must be installed.
All special fittings for adapting the sampling probes to the
ports should be anticipated and fabricated. Arrangements
must be made with plant operating personnel to maintain
steady operating conditions during the test. The test must
be carefully planned as to number and exact location of tra-
verse sample points, and probes should be premarked for
these locations. Flow nomographs for sampling nozzles
should be made; and all filters, impingers, and other ele-
ment of sampling trains should be tared. With that advance
preparation a 3 man sampling team would require 1–2 days
to position their equipment and make gas flow measure-
ments and 2 sample transverses at right angles in a large
duct or stack.
Measurement of Gas Flow Rates
A preliminary step in determination of emission rates from
a stack is measurement of the gas flow rate. Detailed pro-
cedures in wide use including the necessary attention to
technique have been published by the ASME,^20 ASTM,^19
the Environmental Protection Agency, referred to as EPA,^21
C016_001_r03.indd 822C016_001_r03.indd 822 11/18/2005 1:15:34 PM11/18/2005 1:15:34 PM