PH Stage Reduction from 6 to 5 Stage Remarks/
Data Unit 5 Stage 6 Stage Considerations
Total power generation net
( 94 % ) (PH + AQC With
HAR)
MW 13.68 12.41
PH exit operation gas flow m3/hr 1243444 1132394
30 mm pres-
sure drop in a
cyclone
SPC for pH fan (w/o WHRS)
KW / of T
clinker 5.92 5.70^
PH fan operation flow ( with
WHR ) m3/hr^941176896972
70 mm pres-
sure drop
across WHR
boiler
Total Sp. Power generation
net (PH + AQC with HAR)
K W / o f T
clinker 34.55 31.34^
PH fan operation sp. Power
consumption with WHRS
K W / o f T
clinker 5.080 5.088^
Differential PH Fan Sp.
Power consumption
K W / o f T
clinker -0.008 0.000^
Differential Bucket elevator
Sp. Power consumption
KW / of T
clinker -0.100 0.000^
Total Saving on Power
(including generation)
K W / o f T
clinker 34.7 31.3^
Saving for power
generation (Net ) (+)
Rs lacs / year 7389 6682
Cost on additional Sp. Heat
consumption (-)
Lacs Rs/ year 627 0
Total Opex Lacs Rs/ year 6762 6682
Differential Opex Lacs Rs/ year 80 0
Capex