technical NOTES

(Project Pridr) #1

10. Preheater Cyclone Size


During discussion in one of the project on Preheater cyclone sizing & design the
specific requirement given to all suppliers are



  • 350 mmwg pressure at fan inlet on guaranteed output – To reduce the PH fan
    specific power consumption as low as possible, 350 mm is the minimum PH
    fan inlet guaranteed draft offered by suppliers for the first time.

  • Bigger Sizing of PH Cyclone - To have lower volumetric loading < 1 tpd/m3 than
    standard and also better future potential on capacity & efficient heat transfer
    will lead to slow and uniform heating of raw mix so that higher calcination can
    be attained in PH tower itself resulting in leaser work for kiln enabling to
    have lower thermal loading inside the kiln and improved refractory life. Also no
    CO and coating in preheater cyclones and risers.
    10.1 Preheater Cyclone Size- Standard V/S. Offered Sizing


Pre-Heater Cyclone Size
Data Unit S1 S2 S3 S4
Standard Sizing (Double Insulation Estimated)
Preheater cyclone Volume
(Cylinder + Cone) Effective
(Approx.)

m^38359889872008052

Preheater (Cyclone + Riser +
Meal Chutes) surface area m2^97051021185818648
Supply + Fabrication Weight
(Approx.) Ton^1938178412761384
Concrete Volume (RCC -
Approx.) m3^927286251060314312
Preheater cyclone loading at
Guaranteed output tpd/m3 0.9 0.8 1.0 0.9
Pressure Drop Across PH mmWG 381 529 456 412
Offered Sizing

Preheater Cyclone Dimensions mm

2 x 8200
2 x 9000
2 x 9000
2 x 9000
2 x 9000
2 x 9000

4 x 7680
2 x 9500
2 x 9500
2 x 9500
2 x 9500
2 x 9500

4 x 8340
2 x 9180
2 x 9690
2 x 9690
2 x 10240
2 x 10240

2 x 7600
2 x 8000
2 x 8600
2 x 8600
2 x 8600
2 x 8600