Power Plant Engineering

(Ron) #1

STEAM POWER PLANT 165


Coal and
Primary AirA
Sec. Air

Furnace Molten
Slag

Sec.
Air

Coal and
Primary
air

Section at A.A
(c)
(d) (e)

A

Fig. 4.29. Various Types of Burners.

Economizer

Air
Preheater

To s t a c k

Boiler
Tu b e s

Boiler Drum Convection
Super Heater

Water Wall

Pulverised Coal
Burner

Fig. 4.30. Pulverised Coal-fired Boiler.
(i) It saves the cost of pulverisation because of a crusher needs less power than a pulveriser.
(ii) Problem of fly ash is reduced. Ash produced is in the molten form and due to inclination of
furnace it flows to an appropriate disposal system.


Fig. 4.30 shows a pulverised coal-fired boiler.
Free download pdf