STEAM POWER PLANT 165
Coal and
Primary AirA
Sec. Air
Furnace Molten
Slag
Sec.
Air
Coal and
Primary
air
Section at A.A
(c)
(d) (e)
A
Fig. 4.29. Various Types of Burners.
Economizer
Air
Preheater
To s t a c k
Boiler
Tu b e s
Boiler Drum Convection
Super Heater
Water Wall
Pulverised Coal
Burner
Fig. 4.30. Pulverised Coal-fired Boiler.
(i) It saves the cost of pulverisation because of a crusher needs less power than a pulveriser.
(ii) Problem of fly ash is reduced. Ash produced is in the molten form and due to inclination of
furnace it flows to an appropriate disposal system.
Fig. 4.30 shows a pulverised coal-fired boiler.