292 POWER PLANT ENGINEERINGHeat ExchangerCombustion
ChamberGases
OutCompressorTu r b i n eGenerator1 25
463
Air inTIdeal
Heat ExchangeConstant Pressure
LinesTu
rb
ine1234 ′^45
62 ′φFig. 9.27 Fig. 9.28Heat supplied = Kp(Tl – T 3 ) = Kp(T 1 – T 2 )
Heat rejected = Kp(T 5 – T 3 ) = Kp(T 4 – T 3 )
(η) Thermal efficiency of theoretical regenerative cycle(η) =12 43
15K(T T) K(T T)
K(T T)pp
p−− −
−For isentropic compression and isentropic expansion thermal efficiency is given byη =22 43
15K(T T) K(T T)
K(T T)−−′ −
−pp
p9.9 Operations and Maintenance Performance
9.9.1 Operation
(a) Starting. Starting sequence of any gas turbine from rest to its rated speed requires a certain
order of events to be accomplished either manually or automatically. The major steps in sequence are
cranking, ignition, acceleration and governing.
The following is typical starting sequence of a gas turbine- Application of control power illuminates all the malfunctions lights.
- Operate ‘Reset switch’ to reset malfunctions circuits: By doing so, malfunction lights go off
and all control devices assume the condition for starting. - Operate “Start” switch to initiate starting sequence. By doing this, lube oil pump and cooling
fan start. If there are separate switch for these, operate these. - When lube oil reaches a preset pressure, the starter is energized and cranking of the engine
begins. - With the cranking of starting of starter, the engine and exhausts ducts are purged of any
combustible gases that might be present. - During the cranking cycle, the fuel boost pump is used and operated to increase fuel pressure.